DSpace Repository

Application of 2-D resistivity survey to groundwater aquifer delineation in a sedimentary terrain: A case study of south-western Nigeria

Show simple item record

dc.contributor.author Aluko, K. O
dc.contributor.author Raji, W. O
dc.contributor.author Ayolabi, E. A
dc.date.accessioned 2022-07-21T13:08:00Z
dc.date.available 2022-07-21T13:08:00Z
dc.date.issued 2017
dc.identifier.citation Aluko, K. O, Raji, W. O and Ayolabi, E. A (2017). Application of 2-D resistivity survey to groundwater aquifer delineation in a sedimentary terrain: A case study of south-western Nigeria. Water Utility Journal 17: 71-79, 2017. en_US
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/846
dc.description.abstract This study demonstrates an application of two-dimensional resistivity surveys to groundwater exploration in a problematic sedimentary terrain where thick clay layers impedes groundwater aquifer recharge. The objectives of the study are to (i) select locations for citing new boreholes and (ii) investigate causes of the failure of the two boreholes previously drilled in the area. Six profiles of 830 m length each were surveyed to probe the subsurface lithologies and their groundwater potentials. Data acquisition system comprised a Super Sting Resistivity Meter, 84 metallic electrodes, and their accessories. Data acquired from the survey were forward modeled and tomographically inverted, using finite difference techniques. Results of the study revealed the different rock layers beneath the survey lines, their spatial distribution and their resistivities. Two new boreholes, BH3 and BH4, drilled based on the inverted 2-D resistivity images are very productive and have respective yields of 46 l/s and 48 l/s in the dry season. The choice of the locations for the new boreholes was informed by the presence of low resistivity structures interpreted as saturated (wet) sand, good vertical and lateral extents of the saturated sands, the depth of the aquifer in relation to the water table, and the absence of impermeable (sandy clay) cover that could retard groundwater recharge and discharge. The resistivity images of the 2-D survey also show that the failed boreholes – BH1 and BH2 were located on low resistivity structures interpreted as aquifers. But the aquifers have limited vertical and lateral extents, and are adjacent to thick impervious sandy-clay layer. Overall, the study demonstrates the suitability and the superiority of 2D resistivity survey to the traditional 1D – four electrodes survey. en_US
dc.language.iso en en_US
dc.publisher E.W. Publications en_US
dc.relation.ispartofseries 17;
dc.subject Groundwater aquifer en_US
dc.subject Sedimentary terrain en_US
dc.subject 2-D electrical resistivity survey en_US
dc.subject Finite difference techniques en_US
dc.subject Groundwater development en_US
dc.title Application of 2-D resistivity survey to groundwater aquifer delineation in a sedimentary terrain: A case study of south-western Nigeria en_US